MDT-SCN-SAFE.01 Safety Module 2SU MDRC
zoom_out_map
chevron_left chevron_right

MDT-SCN-SAFE.01 Safety Module 2SU MDRC

The new MDT security module prevents all connection-oriented accesses of the ETS, such as the programming and also the unloading of the bus devices, in the KNX line. This significantly increases the safety of the protected line in the inner and in the outdoor area.A manipulation of the device programming is no longer possible. The safety function is started automatically after bus voltage recovery / programming of the safety module. The deactivation of the safety function is possible depending on the set safety level via the control buttons on the device and /or with the safety password via telegramm. The integrated device monitoring system controls up to 100 KNX devices cyclically. As soon as a device is missing or no longer responds due to a defect, an alarm message is sent.

AED0.00
Tax included 2 Working Days
warning Last items in stock
 

Security policy

 

Delivery policy

 

Return policy

Description

  • Production in Germany, certified according to ISO 9001
  • Increases the safety of the protected line in the inner and in the outdoor area and protects against manipulations
  • Easy retrofitting in existing KNX installations
  • Blocks the connection and prevents the programming and unloading of KNX devices within the line
  • Safety function is started automatically after bus voltage recovery and/or programming of the Safety Module
  • Safety function can be temporally disabled by pressing the button on the device or 14Byte telegram
  • Safety function for detecting a failed device in the line
  • Active or passive monitoring of up to 100 KNX devices
  • Alarm is stored as plain text message in the internal ring memory
  • Quick application download (long frame support for ETS5)
  • Integrated bus coupling unit
  • 3 years warranty

Data sheet

Reviews

No customer reviews for the moment.

Write your review

MDT-SCN-SAFE.01 Safety Module 2SU MDRC

The new MDT security module prevents all connection-oriented accesses of the ETS, such as the programming and also the unloading of the bus devices, in the KNX line. This significantly increases the safety of the protected line in the inner and in the outdoor area.A manipulation of the device programming is no longer possible. The safety function is started automatically after bus voltage recovery / programming of the safety module. The deactivation of the safety function is possible depending on the set safety level via the control buttons on the device and /or with the safety password via telegramm. The integrated device monitoring system controls up to 100 KNX devices cyclically. As soon as a device is missing or no longer responds due to a defect, an alarm message is sent.