MDT-STC-0640.01 Bus Power Supply with diagnostic function 4SU MDRC, 640mA
AED0.00
Tax included
Last items in stock
0 Review(s) 
The MDT KNX Power Supply with integrated choke supplies the KNX Bus with a constant, stabilized 30VDC voltage. The integrated bus coupling unit with diagnostic function monitors the bus voltage, bus current, bus overload and bus voltafe failure/return. All events are stored with time stamp in the internal ring buffer. The current operating status is indicated via 8 colored LED on top of the device:
MDT-STC-0960.01 Bus Power Supply with diagnostic function 6SU MDRC, 960mA
AED0.00
Tax included
Last items in stock
0 Review(s) 
The MDT KNX Power Supply with integrated choke supplies the KNX Bus with a constant, stabilized 30VDC voltage. The integrated bus coupling unit with diagnostic function monitors the bus voltage, bus current, bus overload and bus voltafe failure/return. All events are stored with time stamp in the internal ring buffer. The current operating status is indicated via 8 colored LED on top of the device:
MDT-STC-1280.01 Bus Power Supply with diagnostic function 6SU MDRC, 1280mA
AED0.00
Tax included
Last items in stock
0 Review(s) 
The MDT KNX Power Supply with integrated choke supplies the KNX Bus with a constant, stabilized 30VDC voltage. The integrated bus coupling unit with diagnostic function monitors the bus voltage, bus current, bus overload and bus voltafe failure/return. All events are stored with time stamp in the internal ring buffer. The current operating status is indicated via 8 colored LED on top of the device:
MDT-STR-0640.01Redundant Bus Power Supply with diagnostic function 6SU MDRC, 640mA
AED0.00
Tax included
Last items in stock
0 Review(s) 
The MDT KNX Power Supply with integrated choke supplies the KNX Bus with a constant, stabilized 30VDC voltage. The redundant Bus Power Supply has two integrated power supplies to increase operation reliability. If one mains voltage or one of the internal power supplies fails, the KNX bus voltage keeps stable by the second power supply. The integrated bus coupling unit with diagnostic function monitors the bus voltage, bus current, bus overload and bus voltage failure/return. All events are stored with time stamp in the internal ring buffer. The ring buffer can be read out by a 14Byte telegram.
MDT-SCN-RTC20.01 Time Switch with LCD display 6SU, with 20 channels. 6 cycle times each channel
AED0.00
Tax included
Last items in stock
0 Review(s) 
The MDT Time switch with 20 channels (6 cycle times each channel) has a daily/weekly/astro switching function and an adequate power reserve if the bus voltage fails. The cycle times of the single channels are adjustable by the ETS or can be set directly at the device. The large LCD display for comfortable handling allows direct switching of the 20 channels (Manual Mode).
MDT- SCN-LOG1.02 Logic Module 2SU MDRC
AED0.00
Tax included
Last items in stock
0 Review(s) 
The MDT Logic Module is used for fast and easy compilation of logical functions to control building automation systems. All the functions are parametrized directly in the ETS without additionally software tools. There are 24 independent function blocks with arbitrary functions available. For each function a description can be stored in the ETS. The 4 LEDS on the front panel can be controlled optional by objects. According to date, time and location the Logical Module calculates sunset, sunrise and twilight. Additionally there are output objects available for sommer/winter time, calendar week, day of the week, every hour, every minute, day/night.
MDT-SCN-SAFE.01 Safety Module 2SU MDRC
AED0.00
Tax included
Last items in stock
0 Review(s) 
The new MDT security module prevents all connection-oriented accesses of the ETS, such as the programming and also the unloading of the bus devices, in the KNX line. This significantly increases the safety of the protected line in the inner and in the outdoor area.A manipulation of the device programming is no longer possible. The safety function is started automatically after bus voltage recovery / programming of the safety module. The deactivation of the safety function is possible depending on the set safety level via the control buttons on the device and /or with the safety password via telegramm. The integrated device monitoring system controls up to 100 KNX devices cyclically. As soon as a device is missing or no longer responds due to a defect, an alarm message is sent.
MDT-BE-GT20W.01 Glass Push Button II Smart 4/6/8/12-fold, White, Colored display and RGB status indicator
AED0.00
Tax included
0 Review(s) 
The MDT Glass Push Button II Smart releases KNX telegrams after touching the sensor areas on top, 1 or 2 Button operation can be adjusted. The device provides extensive functions like switching of lighting, operation of blinds and shutters, contact type and block communication objects for each channel. The Glass Push Button has 4 integrated logical modules.The Glass Push Button II Smart has a large, coloured active display to indicate funtion and status. Up to 12 functions on 2 or 3 levels (2x6 or 3x4 functions)can be parameterized. The Glass Push Button II Smart can be also used as 6-fold push button without function levels.(From Hardware Revision 2.0)